The correct installation steps and key points of slurry pump


Preparation work before installation

Before installing the slurry pump, a series of preparatory work needs to be carried out, including cleaning, foundation preparation, dimensional measurement, and environmental requirements

Cleaning work: Remove debris inside and outside the equipment to ensure a clean appearance and unobstructed pipelines.

Preparation of foundation: Conduct a survey on the foundation to ensure that it is flat, has strong bearing capacity, is not easily deformed, and must be controlled according to requirements.

Dimensional measurement: Confirm the required dimensions and weight information of the equipment, ensure that the equipment selection meets the requirements, and can adapt to production requirements.

Environmental requirements: Pay attention to whether the environmental conditions are sufficient, including harsh environments, climate, temperature, and other factors, which need to be adjusted according to the actual situation.

Installation process

The specific process of installing slurry pump includes the following steps:

Installation of pump body: Determine the direction and horizontal line of the pump, find the center of the pump to form a road, then place the base and fix the pump base with screws.

Connect the inlet pipeline: Install the inlet pipeline, and the pump pipe inlet should be kept straight. The angle of the pipeline should not exceed 6 ° and must meet the standard diameter requirements.

Connect the outlet pipeline: Connect the outlet pipeline through flanges to ensure safe and effective operation of the pump.

Installation of motor: Clean the housing and sliding parts, lift the motor, insert it into the base and pump feet, then insert the shaft sleeve of the motor into the pump shaft, and finally tighten the bolts between the motor base and the base.

Installation of transmission device: Determine the distance between the axis and other directions, adjust the position of the transmission shaft, and install according to the recommended installation position.

Sealing and filling material: Seal the pipeline and determine if there is any water leakage, especially when installing the conveying pump. It is necessary to prevent slurry from entering the pump pipe and causing pipeline blockage.

Connect the power supply: Connect all installed devices to the power supply, and then perform debugging and inspection work.

Debugging phase

After installation, it is necessary to debug the slurry pump to ensure its normal operation:

Manual testing: Before officially using the slurry pump, the equipment needs to be tested.

Start trial operation: After the testing work is completed, conduct a trial operation to test whether the pump can work normally in a short period of time.

Adjust parameters: If there is an abnormal situation, it is necessary to check and adjust the corresponding parameters to confirm that the slurry pump can work normally. When adjusting parameters, it is necessary to make adjustments based on the actual situation before further testing work.

Routine maintenance: After equipment debugging is completed, routine maintenance is required, including weekly or monthly cleaning and inspection, to ensure long-term stable operation of the equipment.

precautions

When installing the slurry pump, the following points should also be noted:

Check the mechanical seal: Check whether the model and specifications of the mechanical seal of the slurry pump are correct, and whether the dimensional accuracy, geometric accuracy, and interrelationships of the parts related to the installation of the mechanical seal meet the technical requirements.

Keep clean: During the installation process, keep it clean and do not use tools to strike the seals to prevent damage.

Oil coating treatment: Apply a layer of clean oil and transparent oil on the surfaces of the moving and stationary rings. Before installing the auxiliary sealing rings (including the moving ring sealing ring and the stationary ring sealing ring), apply another layer of clean oil or transparent oil to ensure smooth installation.

Correct installation of seals: Place the static ring sealing ring around the back of the static ring and into the sealing end cover. Be careful not to damage the end face of the static ring, ensuring that it is perpendicular to the centerline of the end cover. Pay attention to aligning the anti rotation groove on the back of the static ring with the anti rotation pin, but do not touch it.

By following the above installation steps and key points, the correct installation of the slurry pump can be ensured, thereby ensuring its long-term stable operation.

  This article originates from https://www.fuyangpumps.com/news/398.html. Please indicate the source when reprinting.

(Editor in charge: Slurry Pump https://www.fuyangpumps.com/)

CONTACT US

  • Contact person: Manager Wang
  • Mobile: 86 15188770013
  • Tel: 86 312-3427818
  • Fax: 86 312-3421668
  • WhatsApp: 86 15188770013
  • Wechat: ymm3427
  • Q Q: 357577440
  • Email: fuyangby@126.com
  • website:https://www.fuyangpumps.com/
  • Address: Industrial Park, Anguo City, Hebei Province
  • Wechat

  • WhatsApp

Copyright © Hebei Fuyang Pump Industry Co., Ltd.