Maintenance and Prevention of Slurry Pump Motor Malfunctions


maintenance methods

Remove residues inside the pump casing: Ensure that the interior of the pump casing is clean to avoid residues affecting the operation of the motor.

Using oxygen acetylene to remove impurities from the pump: heating both the pump itself and the guard plate can help remove stubborn impurities.

Surface polishing treatment: Polish the overcurrent area and protective plate inside the pump until the original metal color is exposed, providing a good foundation for repair.

Cleaning with anhydrous ethanol: Ensure that the repair area is clean and conducive to material adhesion.

Coating Sorel Carbon Nanopolymer Material: Apply the blended material evenly onto the repair surface of the pump casing and the protective plate, and complete the repair after curing.

preventive measure

Regular inspection and maintenance: Regularly check the insulation and fastening screws of the motor, and promptly deal with any problems found.

Correct installation and use: Ensure that the pump is installed horizontally to avoid vibration and malfunctions caused by improper installation.

Preventing medium leakage: Select appropriate sealing materials and structures to prevent solid materials, dust, or liquid media from entering the interior of the motor.

Timely cleaning of blockages: Regularly clean the pump body and pipelines to prevent blockages from affecting the normal operation of the pump.

Monitoring operation status: Regularly monitor the operation status of the pump, promptly detect and handle abnormal situations.

Through the above maintenance and preventive measures, the occurrence of slurry pump motor failures can be effectively reduced, the service life of equipment can be extended, and the stable operation of the production process can be ensured.

  This article originates from https://www.fuyangpumps.com/news/396.html. Please indicate the source when reprinting.

(Editor in charge: Slurry Pump https://www.fuyangpumps.com/)

CONTACT US

  • Contact person: Manager Wang
  • Mobile: 86 15188770013
  • Tel: 86 312-3427818
  • Fax: 86 312-3421668
  • WhatsApp: 86 15188770013
  • Wechat: ymm3427
  • Q Q: 357577440
  • Email: fuyangby@126.com
  • website:https://www.fuyangpumps.com/
  • Address: Industrial Park, Anguo City, Hebei Province
  • Wechat

  • WhatsApp

Copyright © Hebei Fuyang Pump Industry Co., Ltd.